Your Cart

Victron DC-DC 12/24V 230A Battery Combiner, CYR010230010

FREE
SHIPPING
Victron DC-DC 12/24V 230A Battery Combiner, CYR010230010
Brand Victron
Seller : Yapıbahçe
6.946,70 TL
Excluding Taxes: 5.788,92 TL
Contribute to reducing Co2 emissions by purchasing this product!

Estimated Delivery: Within 3 days

12/24V 230A Battery Combiner, CYR010230010, Victron

Model No: Cyrix-ct 12/24V-230A intelligent combiner

Intelligent battery monitoring to prevent unwanted transients

Some battery combiners (also called a voltage-controlled relay or split-charge relay) disconnect the battery in the event of a fault.

short but high amperage load. A battery splitter may also not be able to connect a large but discharged battery pack because

The DC voltage drops below the cut-out value immediately when batteries are connected.

The Cyrix-ct 12/24's software does more than simply connect and disconnect based on battery voltage.

fixed time delay. Cyrix-ct 12/24 looks at the general trend (voltage increase or decrease) and reverses the previous situation

take action only if the trend reverses within a certain period of time. Time delay depends on voltage deviation

from trend.

(For Battery Combiners with multiple arm/disarm profiles, please see Cyrix-i 400)

Long bolts allow connecting multiple power cables

Cyrix 12/24-120: 13mm (M6) Cyrix 12/24-230: 16mm (M8)

Protection against overheating (e.g. due to prolonged overload)

Cyrix will be disabled in case of excessive contact temperature and will be activated again after it has cooled down.

LED status indicator (Cyrix 12/24 230 only)

LED on: enabled LED flashing for 10 seconds: disabled

LED flashing for 2 sec: connecting LED flashing for 2 sec: disconnecting

LED flashing for 0.25 s: alarm (overtemperature; voltage > 16 V; both batteries < 10 V; one battery < 2 V)

(multiply by two for 24V)

12/24V auto range

Cyrix-ct 12/24 automatically detects system voltage.

No voltage loss

Cyrix battery combiners are an excellent alternative to diode isolators. Its main feature is that it is almost non-existent.

voltage loss, so there is no need to increase the output voltage of alternators or battery chargers.

Prioritizing the starter battery

In a typical installation, the alternator is connected directly to the starter battery. accessory battery and possibly a

The bow thruster and other batteries are each connected to the starter battery with Cyrix battery couplers. When Cyrix

detects when the starter battery has reached the connection voltage at which it will be activated to charge the other battery in parallel

batteries.

Bi-directional voltage detection and power supply from both batteries

Cyrix detects the voltage of both connected batteries. Therefore, it will also be activated when, for example, an accessory is used.

The battery is being charged by the battery charger.

Cyrix-ct has a 12/24 dual power supply. Therefore, it will also shut down if the voltage on a battery is too low to start.

Cyrix.

Cyrix-ct to prevent unexpected operation during installation or when a battery is disconnected

If the voltage at either battery connection is less than 2 V (12 V battery) or 4 V (24 V), the 12/24 will not turn off.

battery).

Parallel connection in case of emergency (Startup Assist)

Cyrix can also be armed with a push button (Cyrix remains armed for 30 seconds) or a switch to connect.

connect the batteries in parallel manually.

This is especially useful in emergency situations where the starter battery is discharged or damaged.

This product Sent by the seller Yapıbahçe.
The price of the product you have examined is determined by the seller.

    

You can go to the My Orders section under your account and cancel your product if it has not been shipped yet.


If your product has been shipped, how to start the easy return process?


    1. Select the product to be returned and the reason for the return. If you have purchased more than one of the same product, you must also select the number of products to be returned.

    2. Contact us at support@azcarbon.com

    3. Take note of the cargo code that will be sent to you in line with the instructions and enter it in the field on your order screen.

    4. Do not forget to send the invoice with the products to be returned.



After the product reaches us, its compliance with the return conditions is checked.


Product If it meets the return conditions, your return will be approved, otherwise it will be sent back to your address.


The refund of your approved order depends on your bank. Your payment will be reflected on your card within 2-10 business days.


Refund for installment purchases will be made at once. It is made to your bank, but it is displayed in installments on the card statements.


After receiving the product, it must be installed by the authorized service. For your orders in the energy efficiency and mobility category of white goods such as refrigerators, washing machines, televisions, solar panels, inverters;


The package should not be opened without the knowledge of the authorized service; if it is opened, the product will be excluded from the scope of return.


If a problem is detected during the authorized service installation, you can only return the product with an authorized service report.